  • Ultrasonic measurement of apparent and theoretical wind speed and direction
  • Barometric pressure
  • Air and wind chill temperature
  • GPS position speed over ground course over ground
  • Two-axis solid-state compass provides heading data
  • Three-axis accelerometer for best-in-class pitch and roll information
  • Housing IPX6 rated for water-ingress protection
  • Data output via a single cable (various lengths available)
    • NMEA 0183/ASCII serial protocol over RS-232 interface
    • NMEA 2000 protocol over CAN

The WeatherStation 150WX is designed for land-based weather monitoring—particularly mobile applications. With a built-in GPS and electronic compass it is the model of choice for portable or mobile situations. This is based on its GPS position and time-stamping functionality and a compass which self-aligns to north. Orienting the sensor to north is not required.

Theoretical wind speed and direction are important for many applications and often mission-critical. On moving vehicles the 150WX calculates the theoretical wind speed and direction based upon the apparent wind speed of the vehicle and vehicle heading.

Packed with features and encased in a durable rugged small-footprint housing that is IPX6 rated the 150WX can be deployed as an integral component of a larger system. It has been successfully used with the JBTDS HazMat program and on OEM’s mobile agricultural platforms.

Specifications

Wind Speed:

  • Range: 0 to 40 m/s (0 to 89 MPH)
  • Accuracy: 5% at 10 m/s at 4 angles
  • Resolution: 0.1 m/s
  • Calculations: User configurable damping

Wind Direction:

  • Range: 0 to 359.9°
  • Accuracy: ±3° at 10 m/s
  • Resolution: 0.1°
  • Calculations: User configurable damping

Air Temperature:

  • Range: -40 to 80°C (-40 to 176°F)
  • Accuracy: ±1.1°C at 20°C
  • Resolution: 0.1°C

Barometric Pressure:

  • Range: 300 to 1100 hPa
  • Accuracy: ±0.5 hPa at 25°C (or better)
  • Resolution: 0.1 hPa

Two-axis Compass:

  • Range: 0 to 359.9°
  • Accuracy: 1° RMS when level
  • Resolution: 0.1°

Pitch and Roll:

  • Measurement Type: MEMS
  • Range: 50°
  • Accuracy: ±1° in range of ±30°
  • Resolution: 0.1°

Relative Humidity:

  • Range: 0 to 100% RH
  • Accuracy: ±5% RH at 0 to 90% RH at 20°C
  • Resolution: 0.1% RH

Power:

  • Supply Voltage: 9 to 40 VDC
  • Supply Current: <75 mA (<0.9 W) at 12 VDC
  • NMEA 2000® Load Equivalency Number (LEN): 2

Communications:

  • Available Interface: Serial RS-232 Serial RS-422 CAN
  • Available Protocol: Comma delimited ASCII NMEA 0183 NMEA 2000
  • Serial Output Rate: 1 Hz typical. User selectable. 10 Hz maximum recommended

Other:

  • Weight: 300 g (0.7 lb.)
  • GPS Position Accuracy: 3 m (10\') CEP
  • Operating Temperature Range: -25 to 55°C C (-13 to 131°F)
  • Mounting-thread Size on Base: Standard 1\"-14 UNS (3/4\" NPT optional)
  • Certifications and Standards: CE IPX6 (IPX4 with optional Relative Humidity sensor) RoHS IEC61000-4-2 IEC60945 IEC60950_1C IEC60950_22A EN55022 EN55024 EN15014982
View full details